Regulating Flooding of Fluid through Engineering Practices
Monday, May 5, 2014
Thursday, April 10, 2014
Flow Diversion Valve
![]() |
| Waukesha Cherry Burrel Diversion Valve |
Flow Diversion Valve: It is a valve to divert flow in the fluid line. It works on the signal coming from the temperature sensor/Transducer to divert the flow of the fluid. The Waukesha Cherry-Burrell Flow diversion valve is excellent in operational use in the factory. The dairy firms uses this kind of valve to divert the flow of the fluid before the pasteurizer line. The Pasteurizer need above 90 degree Celsius temperature, if the temperature of the fluid is less than 90 degree then the temperature transducer gives signal to the diversion valve and then the diversion valve divert the fluid to the Balance Tank. In the other hand if the temperature is above 90 degree Celsius then the diversion valve is operates to the forward direction .
For details in PDF form the link is given below:
Samson Single acting steam flow control Positioner
Application:
Single-acting positioners for attachment to pneumatic control valves. These positioners use an electric input signal from 0/4to 20 mA or 1 to 5 mA (Type 4763) or a pneumatic input signal from 0.2 to 1 bar (3 to 15 psi) (Type 4765)
Website: http://www.samson-usa.com/us-positioners001.htm
Single-acting positioners for attachment to pneumatic control valves. These positioners use an electric input signal from 0/4to 20 mA or 1 to 5 mA (Type 4763) or a pneumatic input signal from 0.2 to 1 bar (3 to 15 psi) (Type 4765)
Website: http://www.samson-usa.com/us-positioners001.htm
| Positioner Attachment |
Tuesday, April 1, 2014
PARTS OF VALVE
PARTS OF VALVE
Valve Definition: Which regulates the flow of substances (Fluid, Gas) by opening, closing or partially open or close by obstructing.
Major Parts of valve are as follows:
Body, Ports, Discs, Spring, Seat, Stem, Bonnet etc
Body: It is the main part of valves. The substances pass through Body. It is the casing which holds the fluid going inside it. It is made of different metals or plastics.
Ports: The openings, it might be two or more.
Discs: The object which resist or flow the fluid. The shape differs accordingly the types of valve.
Seat: which is used for seal tight between inside and outside.
Stem: It is a rod inside and outside of the valve which transmitting the motion to control the inside disc or rotors..
Bonnet: It is the cover of the valve.
Monday, March 24, 2014
Steam Flow Control Valve
Steam Flow Control Valve
In Industry steam flow needs to be controlled. To control the steam maintenance people use Steam Flow Control Valve. These valve controls the flow of the steam on demand basis in the machine/Process. Controlling of this valves are done normally electrically or pneumatically. Positioner/ Actuator are used for control the flow. The positioner/Actuator are fitted with the valves. Generally for flow control glove valve is used. The actuator respond to the signal by temperature gauges or flow meters. These Steam flow control valves are also named as Automatic Control valve as it is operated through electrically/Pneumatically. Food Processing plant, Dairy foods, refineries, chemical plants, Tobacco Green leaf processing plant are the users of steam flow control valve.
Some Typical application of Steam flow control valve are as follows:
> Fluid Heat Exchangers
> Sterilizer
> Humidifier
> Steam fired Absorption Chiller
> CIP (Cleaning In Place)
There are some good companies who have manufacturing steam flow control valve such as Honeywell, SpiraxSarco, Siemens, Coulton, Flow stream, ARI valves, steriflow, Flow serve corporation, etc
Sunday, March 16, 2014
Difference between Gate valve and Globe Valve
Difference between Gate valve and Globe Valve
|
SL No.
|
Globe Valve
|
Gate Valve
|
|
1.
|
Divert the flow at right angles through a circular opening and flow
is controlled by a circular disc which moves towards and ultimately seats on the
beveled edges of the circular opening.
|
Gate valve has a wedge of material which cuts across the flow area
and seats around the circumference of the pipe.
|
|
2.
|
It can be used for wide open, fully closed, or with the disc in an
intermediate position for regulating the flow.
|
It is used for wide open or fully closed, and not for intermediate
flow regulation.
|
|
3.
|
Used for flow controlling
|
For using dividing or for long time closed position it is used.
|
Saturday, March 15, 2014
Difference between Foot Valve and Check Valve
Difference between Foot Valve and Check Valve
A foot valve is used to maintain a nearly full suction pipe
for a pump to enable the pump to lift the liquid into the pump suction. It
decreases the priming loss of pump. The foot valve is used in the suction of
pump in downward direction. It is used to suck the fluid from sump. In sump
fluid the foot valve is installed. It works mainly on gravitational effects
fitted at bottom of the suction pipe of the pump. The flow velocity to keep a
foot valve open is lower than the velocity required keeping a swing or lifting
check valve open. The differential pressure across the foot valve is small.
Check valve works on difference of pressure in inlet and outlet of the valve. Check valve can be fitted anywhere in the pipe line.
Subscribe to:
Posts (Atom)